11.92 5  Configuring
5.9  FB 131  Subroutine: Submagazine-specific machine data bits
Signal descriptions
MANR Submagazine number
When MANR = 1...16 
1)
, the input parameter states the submagazine number for
which the machine data bits are transferred from DB61 to output parameter MD-B.
When MANR = 0, the global machine data bits are output at output parameter MD-B.
MD-B Machine data bits
When MANR = 1...16 
1)
: MD-B = submagazine-specific machine data bits
When MANR = 1...4: MD-B = global machine data bits
F Error bit
The error output carries a "1 signal" when the specified magazine number > 16 
1)
 or
when the submagazine is not defined (MD 7010.0) + n = 0; n > 1...16 
1)
.
_______
1) SINUMERIK 840/840C 1...4 
© Siemens AG  1991  All Rights Reserved      6FC5 197-0AA40-1BP1 5–33
SINUMERIK 840/880 (PJ)