4412 >Direct Transfer Trip INPUT
Phase L1 (>DTT Trip L1)
DTT Direct Trip SP ON
OFF
**LEDBIBO
4413 >Direct Transfer Trip INPUT
Phase L2 (>DTT Trip L2)
DTT Direct Trip SP ON
OFF
**LEDBIBO
4414 >Direct Transfer Trip INPUT
Phase L3 (>DTT Trip L3)
DTT Direct Trip SP ON
OFF
**LEDBIBO
4417 >Direct Transfer Trip INPUT 3ph
L123 (>DTT Trip L123)
DTT Direct Trip SP ON
OFF
**LEDBIBO
4421 Direct Transfer Trip is switched
OFF (DTT OFF)
DTT Direct Trip OUT ON
OFF
**LEDBO51211Yes
4422 Direct Transfer Trip is BLOCKED
(DTT BLOCK)
DTT Direct Trip OUT ON
OFF
ON
OFF
* LED BO 51 22 1 Yes
4432 DTT TRIP command - Only L1
(DTT TRIP 1p. L1)
DTT Direct Trip OUT * ON * LED BO 51 32 2 No
4433 DTT TRIP command - Only L2
(DTT TRIP 1p. L2)
DTT Direct Trip OUT * ON * LED BO 51 33 2 No
4434 DTT TRIP command - Only L3
(DTT TRIP 1p. L3)
DTT Direct Trip OUT * ON * LED BO 51 34 2 No
4435 DTT TRIP command L123 (DTT
TRIP L123)
DTT Direct Trip OUT * ON * LED BO 51 35 2 No
5203 >BLOCK frequency protection
(>BLOCK Freq.)
Frequency Prot. SP ON
OFF
* * LED BI BO 70 176 1 Yes
5206 >BLOCK frequency protection
stage f1 (>BLOCK f1)
Frequency Prot. SP ON
OFF
* * LED BI BO 70 177 1 Yes
5207 >BLOCK frequency protection
stage f2 (>BLOCK f2)
Frequency Prot. SP ON
OFF
* * LED BI BO 70 178 1 Yes
5208 >BLOCK frequency protection
stage f3 (>BLOCK f3)
Frequency Prot. SP ON
OFF
* * LED BI BO 70 179 1 Yes
5209 >BLOCK frequency protection
stage f4 (>BLOCK f4)
Frequency Prot. SP ON
OFF
* * LED BI BO 70 180 1 Yes
5211 Frequency protection is switched
OFF (Freq. OFF)
Frequency Prot. OUT ON
OFF
* * LED BO 70 181 1 Yes
5212 Frequency protection is
BLOCKED (Freq. BLOCKED)
Frequency Prot. OUT ON
OFF
ON
OFF
* LED BO 70 182 1 Yes
5213 Frequency protection is ACTIVE
(Freq. ACTIVE)
Frequency Prot. OUT ON
OFF
* * LED BO 70 183 1 Yes
5232 Frequency protection: f1 picked
up (f1 picked up)
Frequency Prot. OUT * ON
OFF
* LED BO 70 230 2 Yes
5233 Frequency protection: f2 picked
up (f2 picked up)
Frequency Prot. OUT * ON
OFF
* LED BO 70 231 2 Yes
5234 Frequency protection: f3 picked
up (f3 picked up)
Frequency Prot. OUT * ON
OFF
* LED BO 70 232 2 Yes
5235 Frequency protection: f4 picked
up (f4 picked up)
Frequency Prot. OUT * ON
OFF
* LED BO 70 233 2 Yes
5236 Frequency protection: f1 TRIP (f1
TRIP)
Frequency Prot. OUT * ON * LED BO 70 234 2 Yes
No. Description Function Type
of In-
for-
matio
n
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log ON/OFF
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Inputs
Function Key
Relay
Chatter suppression
Type
Information Number
Data Unit
General Interrogation

Table of Contents

Other manuals for Siemens siprotec 7SA522

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens siprotec 7SA522 and is the answer not in the manual?

Siemens siprotec 7SA522 Specifications

General IconGeneral
BrandSiemens
Modelsiprotec 7SA522
CategoryProtection Device
LanguageEnglish

Related product manuals