Appendix
A.11 Measured Values
SIPROTEC, 7SK80, Manual
E50417-G1140-C344-A4, Release date 08.2010
471
889 Pulsed Energy Wq (reactive) (Wq(puls)) Energy 133 56 No 205 - CFC
901 Power Factor (PF =) Measurement 134 157 No 9 14 CFC
924 Wp Forward (WpForward) Energy 133 51 No 205 - CFC
925 Wq Forward (WqForward) Energy 133 52 No 205 - CFC
928 Wp Reverse (WpReverse) Energy 133 53 No 205 - CFC
929 Wq Reverse (WqReverse) Energy 133 54 No 205 - CFC
963 I A demand (Ia dmd=) Demand meter - - - - - CFC
964 I B demand (Ib dmd=) Demand meter - - - - - CFC
965 I C demand (Ic dmd=) Demand meter - - - - - CFC
1058 Overload Meter Max (Θ/ΘTrpMax=) Min/Max meter - - - - - CFC
1059 Overload Meter Min (Θ/ΘTrpMin=) Min/Max meter - - - - - CFC
1068 Temperature of RTD 1 (Θ RTD 1 =) Measurement 134 146 No 9 1 CFC
1069 Temperature of RTD 2 (Θ RTD 2 =) Measurement 134 146 No 9 2 CFC
1070 Temperature of RTD 3 (Θ RTD 3 =) Measurement 134 146 No 9 3 CFC
1071 Temperature of RTD 4 (Θ RTD 4 =) Measurement 134 146 No 9 4 CFC
1072 Temperature of RTD 5 (Θ RTD 5 =) Measurement 134 146 No 9 5 CFC
1073 Temperature of RTD 6 (Θ RTD 6 =) Measurement 134 146 No 9 6 CFC
1074 Temperature of RTD 7 (Θ RTD 7 =) Measurement 134 146 No 9 7 CFC
1075 Temperature of RTD 8 (Θ RTD 8 =) Measurement 134 146 No 9 8 CFC
1076 Temperature of RTD 9 (Θ RTD 9 =) Measurement 134 146 No 9 9 CFC
1077 Temperature of RTD10 (Θ RTD10 =) Measurement 134 146 No 9 10 CFC
1078 Temperature of RTD11 (Θ RTD11 =) Measurement 134 146 No 9 11 CFC
1079 Temperature of RTD12 (Θ RTD12 =) Measurement 134 146 No 9 12 CFC
16004 Threshold Sum Current Exponentiation
(ΣI^x>)
SetPoint(Stat) - - - - - CFC
16009 Lower Threshold of CB Residual Endurance
(Resid.Endu. <)
SetPoint(Stat) - - - - - CFC
16017 Threshold Sum Squared Current Integral
(ΣI^2t>)
SetPoint(Stat) - - - - - CFC
16031 Angle between 3Vo and INsens. (ϕ(3Vo,INs)
=)
Measurement - - - - - CFC
30701 Pa (active power, phase A) (Pa =) Measurement - - - - - CFC
30702 Pb (active power, phase B) (Pb =) Measurement - - - - - CFC
30703 Pc (active power, phase C) (Pc =) Measurement - - - - - CFC
30704 Qa (reactive power, phase A) (Qa =) Measurement - - - - - CFC
30705 Qb (reactive power, phase B) (Qb =) Measurement - - - - - CFC
30706 Qc (reactive power, phase C) (Qc =) Measurement - - - - - CFC
30707 Power Factor, phase A (PFa =) Measurement - - - - - CFC
30708 Power Factor, phase B (PFb =) Measurement - - - - - CFC
30709 Power Factor, phase C (PFc =) Measurement - - - - - CFC
30800 Voltage VX (VX =) Measurement - - - - - CFC
30801 Voltage phase-neutral (Vph-n =) Measurement - - - - - CFC
No. Description Function IEC 60870-5-103 Configurable in Matrix
Type
Information Number
Compatibility
Data Unit
Position
CFC
Control Display
Default Display

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROTEC 7SK80 and is the answer not in the manual?

Siemens SIPROTEC 7SK80 Specifications

General IconGeneral
BrandSiemens
ModelSIPROTEC 7SK80
CategoryProtection Device
LanguageEnglish

Related product manuals