Functions
7.16 User account administration
SIRIUS 3RW55 soft starter
148 Manual, 08/2018, A5E35630887002A/RS-AB/002
User roles and user rights
User administrator
: Creating, editing or deleting all user accounts.
Diagnostics personnel
: Access rights in order to display diagnostic data (without login).
Operating personnel
: Operation of the soft starter under normal operating conditions.
Maintenance personnel
: Maintenance access (control, parameterize, test) to the device.
Diagnostics Control Parameter
assignment
FW update Administration of
user accounts
User administrator
x
Diagnostics
personnel
X
Operating personnel
X
X
Maintenance
personnel
X X X X
User account
It is possible to log in to the soft starter with the username and the four-digit HMI User PIN.
User name
1 ... 32 characters
Numerals, uppercase and lowercase letters, and all special characters are possible
User password
4 ... 32 characters
Numerals, uppercase and lowercase letters, and special characters ?!+%$
Note
A secure password can only be used for a single application, is more than 8 characters long,
and contains uppercase and lowercase, special characters and numerals. It should not
contain any common numeric seq
uences from the computer keyboard or words from the
dictionary. Change your password at regular intervals.
HMI User PIN
4-digit HMI User PIN
Digits 0 ... 9
A login with PIN is only possible via the 3RW5 HMI High Feature
User monitoring time
On expiry of the programmable user monitoring time, the user will be logged out
automatically.