Example circuits
A.3 Special applications
SIRIUS 3RW55 soft starter
222 Manual, 08/2018, A5E35630887002A/RS-AB/002
A.3.5
Reversing duty
WARNING
Automatic restart.
Can cause death or serious injury.
If a starting command is pending, a restart will be triggered automatically after the reset.
This particularly applies if the motor protection has tripped. Dangerous states of the system
can result.
Reset the start command (e.g. via the PLC or switch) before performing a reset.
To do this, for example, link the group error output (terminals 95 and 96) into the control.
Requirements
Parameterization required
Wiring for reversing duty:
S1
Switch: Motor On / Off CW
S2
Switch: Motor On / Off CCW
S3
Pushbutton: Reset
Q1
Motor starter protector
Q11
3RW55 soft starter
Q21
Line contactor CW
Q22
Line contactor CCW
M1
Motor
PE
Protective conductor