The cable shield is physically and electrically terminated within the body of the plug.
Note
Never pull the cable by the plug - only by the cable itself.
1. Connect the external DSL to the transmitter using the supplied 4-wire cable with M12
connectors.
Note
Grounding
The SSL cable shield is only mechanically connected to the grounding terminal (PE), when
the M12 plug is correctly tightened.
M20 connector version
1. Prepare SSL cable by stripping it at both ends.
PPPPPP
2UDQJH
<HOORZ
:KLWH
%OXH
Figure4-13 Cable end
2. Remove cap and ferrule from cable gland and slide onto cable.
3. Remove blind plug and 󹪝t cable gland.
Figure4-14 Connection - SSL cable blind plugs
Connecting
4.7Connecting wall mount enclosure
SITRANS FS130 & FS230
70 Compact Operating Instructions, 12/2023, A5E38755607-AF