The following components may also be used in the Simplex Smoke Control System:
Network Display Unit (NDU).
4010 Fire Alarm Control Panel (FACP).
LCD Annunciator.
Note: The designated FSCS must initiate smoke control commands at the highest priority.
The figure below shows these optional components:
On
Off
Auto
On
Off
Auto
On
Off
Auto
On
Off
Auto
On
Off
Auto
On
Off
Auto
On
Off
Auto
On
Off
Auto
Press ACK located under flashing indicator.
Repeat operati on until all ev ents are acknowl edged.
Local tone will silence.
A B C
AC Power
D E F G H I
J K L M N O P Q R
'SP' ( ) , 0 :
S T U V W X Y Z /
ALARMS
Fire Alarm Priority 2 Alarm
SYSTEM WARNINGS
Supervisory Trouble
Alarm Sile nced
Emergency Operating Instructions
Alarm or Warning Condition
How to Acknowledge / View Events
How to Si lence B uilding S ignals
System indica tor flashing. T one On. Press Alarm Silence.
How to Reset System
Press System Reset.
Press Ack t o silence tone de vice.
ZONE
1
SIG
2
AUX
3
FB
4
IO
5
IDNet
6
P
7
A
8
L
9
NET ADDR
0
DEL
Enter C/Exit
Fire Alarm
Ack
Priority 2
Ack
Supv
Ack
Trouble
Ack
Alarm
Silence
System
Reset
Event
Time
Enable
On
Arm
Disable
Off
Disarm
Auto
Lamp
Test
More
Info
Menu
Previous
Next
SYSTEM IS NORMAL
08:23:43 am MON 11-DEC-00
Fire Control
C
A
U
T
I
O
N
C
A
U
T
I
O
N
DISCONNECT
A.C. POWER
AND
BATTERY
BEFORE
SERVICING
DISCONNECT
A.C. POWER
AND
BATTERY
BEFORE
SERVICING
4100U MINIPLEX
Transponder Cabinet
4100U Fire Alarm Control Panel or
Network Display Unit (NDU) with Voice
Modules and LED/Switch Modules
FIRE
ALARM
ALARM
SILENCED
PRIORITY 2
ALARM
SYSTEM
SUPERVISORY
SYSTEM
TROUBLE
POWER
ON
ALARM
ACK
SUPV
ACK
TBL
ACK
ALARM
ACK
ALARM
SILENCE
SYSTEM
RESET
DISPLAY
TIME
4603-9101 LCD
Annunciator
Fire Alarm Local Mode Controller
ENABLE
CONTROL
Alarm
Alarm
Silenced
Local
Mode
Active
Power
On
Alarm
Silence
Reset
Local
Mode
Control
See Operating Instruction 579-343
4601 Series Transponder
Local Mode Controller
Figure 3-3. Optional Smoke Control System Components
Continued on next page
Optional and Peripheral System Components
Optional System
Components

Table of Contents

Other manuals for Simplex 4100U

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simplex 4100U and is the answer not in the manual?

Simplex 4100U Specifications

General IconGeneral
Control Panel TypeAddressable Fire Alarm Control Panel
DisplayLCD
Power Supply120/240 VAC, 50/60 Hz
Max Signaling Line Circuits (SLC)2
Operating Temperature0°C to 49°C (32°F to 120°F)
Humidity Range10% to 93% non-condensing
Network CapabilityYes
Communication ProtocolRS-232, RS-485
Battery Backup24 VDC
NAC Outputs4
Signaling Line Circuits (SLCs)2
Power Supply Current3.0 A
Max Notification Appliance Circuits (NAC)4
Max Releasing Circuits4
Max Relay Circuits4
Communication PortsRS-232, RS-485