v
Chapter 5 Smoke Control System Programs 5-1
Introduction .............................................................................................................. 5-1
In this Chapter ......................................................................................................... 5-1
Smoke Control Program Requirements ...................................................................... 5-2
Introduction .............................................................................................................. 5-2
Emergency Operation .............................................................................................. 5-2
Automatic Program .................................................................................................. 5-2
Dedicated Smoke Control System Weekly Self-Test .............................................. 5-2
Dedicated Smoke Control System Weekly Self-Test .................................................. 5-3
Custom Control Programming Example .................................................................. 5-3
Equation 1: Start Self-Test ...................................................................................... 5-3
Equation 2: Turn ON Stair Pressure Fan ................................................................. 5-3
Equation 3: Test Stairwell Air Pressure ................................................................... 5-4
Equation 4: Reset Stair Pressure Fan to OFF ......................................................... 5-4
Equation 5: End of Program .................................................................................... 5-4
Smoke Control System Custom Control Equations ..................................................... 5-5
Introduction .............................................................................................................. 5-5
Smoke Control System CC Equation Summary ...................................................... 5-5
Equation 1: Set Up Normal Conditions at Startup ................................................... 5-7
Equation 2: Clear Faults on Startup ........................................................................ 5-7
Equation 3: Set Normal Conditions at Reset ........................................................... 5-8
Equation 4: Set Normal Conditions at Reset ........................................................... 5-8
Equation 5: Initialize Normal Conditions at Reset ................................................... 5-9
Equation 6: Normal Conditions Complete After Reset ............................................ 5-9
Equation 7: Smoke Control Initiate ........................................................................ 5-10
Equation 8: Smoke Control Reset ......................................................................... 5-10
Equation 9: Initiate Smoke Zone 1 ........................................................................ 5-10
Equation 10: Activate Smoke Control Zone 1........................................................ 5-11
Equation 11: Initiate Smoke Zone 2 ...................................................................... 5-11
Equation 12: Activate Smoke Control Zone 2........................................................ 5-12
Equation 13: Initiate Smoke Zone 3 ...................................................................... 5-12
Equation 14: Activate Smoke Control Zone 3........................................................ 5-13
Equation 15: Initiate Smoke Zone 4 ...................................................................... 5-13
Equation 16: Activate Smoke Control Zone 4........................................................ 5-14
Equation 17: Supply Fan Duct Smoke Alarm ........................................................ 5-14
Equation 18: Stair Press Fan Duct Smoke Alarm ................................................. 5-14
Equation 19: Report TBL if Supply Fan Not ON .................................................... 5-15
Equation 20: Report TBL if Supply Fan Not OFF .................................................. 5-15
Equation 21: Report TBL if Exhaust Fan Not ON .................................................. 5-15
Equation 22: Report TBL if Exhaust Fan Not OFF ................................................ 5-15
Equation 23: Report TBL if Stair Press Fan Not ON ............................................. 5-16
Equation 24: Report TBL if Stair Press Fan Not OFF ........................................... 5-16
Equation 25: Report TBL if Main EXH Damper Not Open ..................................... 5-16
Equation 26: Report TBL if Main EXH Damper Not Closed .................................. 5-16
Equation 27: Report TBL if Main SUP Damper Not Open ..................................... 5-17
Equation 28: Report TBL if Main SUP Damper Not Closed .................................. 5-17
Equation 29: Report TBL if Main RET Damper Not Open ..................................... 5-17
Equation 30: Report TBL if Main RET Damper Not Closed .................................. 5-17
Equation 31: Report TBL If SUP Damper 1 Not Open .......................................... 5-18
Equation 32: Report TBL If SUP Damper 1 Not Closed ........................................ 5-18
Equation 33: Report TBL If SUP Damper 2 Not Open .......................................... 5-18
Equation 34: Report TBL If Sup Damper 2 Not Closed ......................................... 5-18
Equation 35: Report TBL If SUP Damper 3 Not Open .......................................... 5-19
Equation 36: Report TBL If SUP Damper 3 Not Closed ........................................ 5-19
Equation 37: Report TBL If SUP Damper 4 Not Open .......................................... 5-19

Table of Contents

Other manuals for Simplex 4100U

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simplex 4100U and is the answer not in the manual?

Simplex 4100U Specifications

General IconGeneral
Control Panel TypeAddressable Fire Alarm Control Panel
DisplayLCD
Power Supply120/240 VAC, 50/60 Hz
Max Signaling Line Circuits (SLC)2
Operating Temperature0°C to 49°C (32°F to 120°F)
Humidity Range10% to 93% non-condensing
Network CapabilityYes
Communication ProtocolRS-232, RS-485
Battery Backup24 VDC
NAC Outputs4
Signaling Line Circuits (SLCs)2
Power Supply Current3.0 A
Max Notification Appliance Circuits (NAC)4
Max Releasing Circuits4
Max Relay Circuits4
Communication PortsRS-232, RS-485

Related product manuals