- 44 -
16642
Version 02
EN
15. Appendices
EN
15. Appendices
4.1 Function button functions
Pressing the function button when the lubri-
cation program is calculating the lubrication
interval will immediately initiate an extra
lubrication cycle, bypassing the pre-set lu-
brication interval value. In DuoFlex systems,
the two lines will be lubricated successively.
The lubrication cycle following the extra
lubrication will be initiated after the pre-set
lubrication interval is complete.
The function button is also used to recover
the system from alarm status after clearing
the cause of the alarm. Acknowledging the
alarm will restart lubrication in the line gen-
erating the alarm.
Pressing the function button when the
program has started pressurisation will
interrupt pressurisation. The program will
continue as if pressurisation had been com-
pleted as normal.
Table 2. Function button functions
Lubrication
program status
Action
Lubrication interval Initiate extra lubrication
Pressurisation Interrupt pressurisation
Alarm Reset alarm
Figure 2
ST-102 control centre function button