Page 25 of 92
Chapter: 2. Operation
Screen status, Menu 5, analogue settings.
Softkey Name Range/value Default value Description Activate with
hidden button
1 MENU 1 - 8 5 Menu 5 is selected.
2 OUT NUM 1 - 3 1 Analogue output channel to be
congured by softkey 3 - 6 (Ch1,
Ch 2, Ch 3).
3 ANA MODE 0 - 10 V
4 - 20 mA
0 - 10 V Select output mode for this channel
(softkey 2).
Yes (1 beep)
4 OUT MODE ForAftWT, LateralWT,
ResultWT, ForAftBT,
LateralBT, ResultBT.
ForAftWT Type of speed value to be output at
selected channel (softkey 2).
Yes (1 beep)
5 ANA MIN -48.6 - 48.4 kn 0.0 kn Speed value, corresponding to
minimum analogue value at
selected channel. Corresponds to
0 V, 4 mA.
Yes (1 beep)
6 ANA MAX -48.4 - 48.6 kn 20.0 kn Speed value, corresponding to
maximum analogue value at
selected channel. Corresponds to
10 V, 20 mA.
Yes (1 beep)
Screen status, Menu 4, pulse settings.
Softkey Name Range/value Default value Description Active with
hidden button
1 MENU 1 - 8 4 Menu 4 is selected.
2 OUT NUM 1 - 3 1 Pulse output channel to be
congured by softkey 3 and 4 (Ch
1, Ch 2 and Ch 3).
Note: If speed limit is activated,
only OUT NUM 2 and 3 are
available.
3 PULSES
NUM
10/100/200/400/1000/nm 200/nm Number of pulses per nautical mile
at selected channel (softkey 2).
Note: 1000/nm only on Ch 3 (OUT
NUM3).
Yes (1 beep)
4 OUT MODE ForAftWT, LateralWT,
ResultWT, ForAftBT,
LateralBT, ResultBT.
ForAftWT Type of speed value to be output at
selected channel.
Yes (1 beep)
5 Not used.
6 Not used.