Page 31 of 92
Chapter: 2. Operation
Screen diagnostics, Menu 1, Details On.
Soft-
key
Name Range/
value
Default
value
Description Activate
with hidden
button
1 MENU 1 - 3 1
2 DIAGNOSTIC On/o O Start self diagnostics procedure, The results will be shown in
the ‘test results’ frame, and advice based on the results, will be
displayed in ‘possible reasons’. More info in section “Typical
diagnostic screen contents.” on page <?>. Note: Diagnostics
not available in Demo/Simulate mode.
3 DETAILS ON/OFF OFF Details O: Only diagnostics results shown
Details On: Doppler signal and frequency of each channel
shown for diagnostics use
4 RECORDINGS On/O O If necessary, the user can log all relevant raw data to the
Compact Flash disk. This data will be stored in an internal
proprietary format that can be analysed upon request.
5 DPT RANGE 5-150m 50m Depth range to be used in the digitizing scope.
6 DIGITIZING Disabled,
wt ch1, wt
ch3, wt ch4,
bt ch1, bt
ch3, bt ch4.
Disabled This function allows to display oscillogram in the graphical
window from any channel in both water track and bottom track
modes. It will allow examining shape and amplitude of the
returned signal in each individual channel. Note: This function
delays signal processing and must be set to “Disabled” during
normal operation to reduce latency of the system.
Yes, (2