Softkey Name Range/value Default
value
Description Activate with
hidden button
1 MENU 1 -8 8 Note: Press MENU softkey and turn
encoder to select menu 8.
2 SPD TEST On/O O Toggling test mode. Yes (1 beep)
3 LONG. SP -40.0 - 40.0 kn 0.0 kn Select test value for longitudinal speed. Yes (1 beep)
4 TRANSV. SP -5.0 - 5.0 kn 0.0 kn Select test value for transversal speed. Yes (1 beep)
5 DISTANCE Auto, 0.00 -
99946.00 NM
Auto Select test value for distance. Yes (1 beep)
6 SIMULATE On/O O Speed simulator on/o.
Screen status, Menu 6, speed limits and hysteresis
Softkey Name Range/value Default
value
Description Activate with
hidden button
1 MENU 1 -8 6
2 SPD LIMIT▲ -48.6 - 48.6 kn 0.0 kn High speed limit value. Yes (1 beep)
3 SPD LIMIT▼ -48.6 - 48.6 kn 0.0 kn Low speed limit value. Yes (1 beep)
4 HYSTERESIS 0.0 - 2.0 kn 0.0 kn Dierence between high and low limit. Yes (1 beep)
5 Not used Not used
6 Not used Not used
Screen status, Menu 7, signal good/signal suspected
Softkey Name Range/
value
Default
value
Description Activate with
hidden button
1 MENU 1 -8 7
2 SIGN. GOOD 6- 90 % 50 % Min. sample % to be qualied as good. Yes (1 beep)
3 SIGN. SUSP(ECTED) 5 - 89 % 25 % Min. sample % to be qualied as suspected. Yes (1 beep)
4 Not used Not used
5 RESET FACTORY Reset Reset of log settings without reset of calibra-
tion I/O settings and trip.
(Alternative to Master reset)
Yes (1 beep)
6 NAUT RULES o/on o See appendic 5 Yes (3 beep)