Page 29 of 92
Chapter: 2. Operation
Screen calibration, Menu 4, mounting settings.
Softkey Name Range/value Default
value
Description Activate with
hidden button
1 MENU 1 - 4 3 Menu 4 is selected.
2
3
4
5 SOUND SURF 1400-1550 Auto Speed of sound in water.at surface Yes (1 beep)
6 SOUND AVER 1400 - 1550 m/s Auto Speed of sound in water. average of STW area Yes (1 beep)
Screen calibration, Menu 3, mounting settings.
Softkey Name Range/value Default
value
Description Activate with
hidden button
1 MENU 1 - 4 3 Menu 3 is selected.
2 Not used.
3 SALINITY 20-35 30 See appendix 5 Yes (1 beep)
4 HEAD ERR -30.0° - 30.0° 0.0° Installation angular error correction.
(Seen by “averaged drift” during speed opera-
tion.)
Yes (1 beep)
5
6 T° OFFSET 10.0°C -10.0°C 0.0°C Temperature oset correction. Yes (1 beep)