Page 67 of 92
Chapter: 7. Specications
7. Specications
Dimensions
Transducer, 3 beam 3 x 270 kHz D x H 99 x 115 mm.
. Mounting Sea valve/tank/retrot.
Cable length 40 m.
Weight app. 10 kg (w/cable).
Transceiver cabinet
H x W x L 450 x 300 x 260 mm.
Weight app. 15 kg.
Operator unit cabinet Height, front 340 mm.
Width 320 mm.
Depth 170 mm.
Weight app. 10 kg.
Operator unit cabinet
Cut-out for ush mounting H x W: 324 x 304 mm.
Corner radius 4 mm.
Functional Properties
Display
• 150 x 200 mm (10.4 inch) LCD with adjustable backlight, 640 x 480 pixels.
Supply voltage
• 115/230 V AC.
• 24 V DC (20-32 V)
Power consumption operator unit
• 50 W at 24 V DC.
• 70 W at 115/230 V AC.
Speed alarms
• High and low limits.
Calendar/clock
• Year-month-day/hours-minutes-seconds (24 hour system).
Interface outputs
• 10/100/200/400/1000 pulses per nautical mile.
• Analogue 4 - 20 mA and 0 - 10 V.
• IEC 61162-1:2007(E) (NMEA 0183) (RS-422).
• Alarm relay change-over contact, max. 24 V 300 mA.
• Output for VGA repeater.
Interface inputs
• IEC 61162-1:2007(E) (NMEA 0183) (RS-422).
Languages
• English.
Options
• IR300 digital speed repeater.
• CD401 LR digital speed repeater.
Protection
• IP 22