EasyManua.ls Logo

Skipper DL850 - Reset Factory Procedure; Master Reset Procedure

Skipper DL850
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Edition: 2017-09-25
Page 66 of 92
Chapter: 6. Trouble Shooting
Master reset: Press down these two softkeys and keep them
pressed during the “power-up” sequence.
Reset factory procedure.
In some cases the display cabinet may get “confused”, or the user has “adjusted” too much. Performing a
“reset factory” procedure will return all values to factory default settings.
The “Reset factory” will not reset calibration, I/O settings (NMEA) or total trip.
To perform “reset factory”, See”RESET FACTORY” on page 26
Master reset procedure.
If “reset factory” did not help performing a master reset procedure will return all values to factory default
settings.
Important note: Before performing this, note your calibration settings, and setup for inputs and outputs as
these will be lost during this procedure.
Switch o the display unit using the internal toggle switch(es) and wait a few seconds.
Then press down and keep pressed the softkey to the far right and far left (no. 1 and 6) in the upper row
on the keyboard (softkeys).
Turn “on” the display unit, and keep the two softkeys pressed down until the screen shows the normal
picture. This may take as long as app. 30 seconds.
You should now normally hear 4 ‘’beeps’’.
Note: You will now have to re-apply your settings for calibration, input/output and screen settings
SKIPPER Electronics AS
Operation and Installation DL850 270 kHz

Table of Contents

Related product manuals