Section 5 – Procedures Deutz Diesel Engines
5.6-6 Deutz TD2.9L Fault Codes
Code SPN FMI Blink Code Error Identification
624 523612 12 555 ECU reported internal software error.
625 523612 12 555 ECU reported internal software error.
627 523612 12 555 ECU reported internal software error.
628 523612 12 555 ECU reported internal software error.
629 523612 12 555 Diagnostic fault check to report the accelerator pedal position error.
630 523612 12 555 Diagnostic fault check to report the engine speed error.
631 523612 12 555 Error in the plausibility of the injection energizing time.
632 523612 12 555 Error in the plausibility of the start of energising angles.
633 523612 12 555 Diagnostic fault check to report the error due to non plausibility in ZFC.
634 523612 12 555
Diagnosis fault check to report the demand for normal mode due to an error
in the PoI2 quantity.
635 523612 12 555
Diagnosis fault check to report the error to demand for an ICO due to an
error in the PoI2 shut-off.
636 523612 12 555
Diagnosis fault check to report the error to demand for an ICO due to an
error in the PoI3 efficiency factor.
637 523612 12 555 Internal ECU monitoring detection reported error.
638 523612 12 555 Monitoring of Fuel Quantity Correction.
639 523612 12 555
Diagnostic fault check to report the plausibility error in rail pressure
monitoring.
640 523612 12 555 Diagnostic fault check to report the error due to torque comparison.
641 523612 12 555 Diagnosis of curr path limitation forced by ECU monitoring level 2.
642 523612 12 555 Diagnosis of lead path limitation forced by ECU monitoring level 2.
643 523612 12 5-5-5 Diagnosis of set path limitation forced by ECU monitoring level 2.
644 523612 3 5-5-5 Reported Over Voltage of Supply.
646 523612 4 5-5-5 Reported UnderVoltage of Supply.
648 523008 1 4-2-4 Manipulation control was triggered.
649 523008 2 4-2-4 Timeout error in Manipulation control.
654 2634 12 7-5-7 Early opening defect of main relay No detailed information!
656 2634 12 7-5-7 DFC for stuck main relay error No detailed information!
659 3226 2 8-1-3 Nox feed back fault detection No detailed information!
692 523752 0 7-5-8 Plausibiliti error during Rich to Lean switch over No detail informationen!
693 523752 0 7-5-8 Monitoring of Nox signal readyness No detail informationen!
714 523612 12 5-5-5
Diagnostic fault check to report WDA active due to errors in query-/response
communication.
715 523612 12 5-5-5 Diagnostic fault check to report ABE active due to undervoltage detection.
716 523612 12 5-5-5 Diagnostic fault check to report ABE active due to overvoltage detection.
717 523612 12 5-5-5 Diagnostic fault check to report WDA/ABE active due to unknown reason.
1513AA-8
To order go to Discount-Equipment.com

Table of Contents

Other manuals for Skyjack SJ82 T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skyjack SJ82 T and is the answer not in the manual?

Skyjack SJ82 T Specifications

General IconGeneral
BrandSkyjack
ModelSJ82 T
CategoryBoom Lifts
LanguageEnglish

Related product manuals