229
SJ82 T, SJ86 T
229040ABA
Deutz Diesel Engines Section 5 – Procedures
5.6-6 Deutz TD2.9L Fault Codes
Code SPN FMI Blink Code Error Identification
720 98 2 2-1-1
Plausibility Check.
No detailed information!
732 100 3 2-2-4 Sensor error oil pressure; signal range check high.
733 100 4 2-2-4 Sensor error oil pressure sensor; signal range check low.
734 100 0 2-3-1 High oil pressure; warning threshold exceeded.
735 100 0 2-3-1 High oil pressure; shut off threshold exceeded.
736 100 1 2-3-1 Low oil pressure; warning threshold exceeded.
737 100 1 2-3-1 Low oil pressure; shut off threshold exceeded.
743 175 3 1-4-4 Sensor error oil temperature; signal range check high.
744 175 4 1-4-4 Sensor error oil temperature; signal range check low.
745 175 0 1-4-4 High oil temperature; warning threshold exceeded.
746 175 0 1-4-4 High oil temperature; shut off threshold exceeded.
747 1237 2 1-4-5 Override switch; plausibility error.
750 107 3 1-3-6 Sensor error airfilter differential pressure; short circuit to battery.
751 107 0 1-3-6 Sensor error airfilter differential pressure; short circuit to ground.
752 107 0 1-3-6 Air filter differential pressure; air filter cologged.
753 523919 2 6-9-4 DPF burner air pump pressure sensor, plausibility error.
755 523919 0 6-9-4
DPF burner air pump pressure sensor, pressure above upper shutoff
threshold.
758 523919 1 6-9-4
DPF burner air pump pressure sensor, pressure below lower shutoff
threshold.
761 523919 3 6-9-4 DPF burner air pump pressure sensor, short circuit to battery or open load.
762 523919 4 6-9-4 DPF burner air pump pressure sensor, short circuit to ground.
763 523920 2 7-1-6 Exhaustgaspressure upstream burner, plausibility error.
765 523920 0 7-1-6
Exhaust gas pressure upstream burner, pressure above upper shutoff
threshold.
770 523920 3 7-1-6 Exhaust gas pressure upstream burner, short circuit to battery or open load.
771 523920 4 7-1-6 Exhaust gas pressure upstream burner, short circuit to ground.
772 102 2 2-2-3 Pressure downstream charge air cooler, plausibility error.
774 102 1 2-2-3
Pressure downstream charge air cooler, pressure below lower physical
threshold.
776 102 3 2-2-3 Pressure downstream charge air cooler, short circuit to battery or open load.
777 102 4 2-2-3 Pressure downstream charge air cooler, short circuit to ground.
780 523699 3 1-1-3 Boost pressure control; negative governor deviation below limit.
781 523699 4 1-1-3 Learning value too high. No detailed information!
785 523889 3 1-1-3
Over temperature of device driver of pressure control valve. No detailed
information!
1513AA-9
To order go to Discount-Equipment.com

Table of Contents

Other manuals for Skyjack SJ82 T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skyjack SJ82 T and is the answer not in the manual?

Skyjack SJ82 T Specifications

General IconGeneral
BrandSkyjack
ModelSJ82 T
CategoryBoom Lifts
LanguageEnglish

Related product manuals