Section 5 – Procedures Deutz Diesel Engines
5.6-6 Deutz TD2.9L Fault Codes
Code SPN FMI Blink Code Error Identification
1023 51 5 5-9-4
Actuator error EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8); signal range
check low.
1024 51 3 5-9-4
Position sensor error of actuator EGR-Valve (2.9;3.6) or Throttle-Valve
(4.1;6.1;7.8).
Signal range check high.
1025 51 4 5-9-4
Position sensor error actuator EGR-Valve (2.9;3.6) or Throttle-Valve
(4.1;6.1;7.8).
Signal range check low.
1026 4769 2 6-8-4 Temperature downstream DOC, plausibility error.
1029 4766 0 6-8-4 Temperature downstream DOC, temperature above upper shutoff threshold.
1030 4766 0 6-8-4 Temperature downstream DOC, temperature above upper warning threshold.
1034 4769 3 6-8-4
Sensor error exhaust gas temperature downstream (DOC); signal range
check high.
1035 4769 4 6-8-4
Sensor error exhaust gas temperature downstream (DOC); signal range
check low.
1036 4768 2 6-8-3 Temperature upstream DOC, plausibility error.
1039 4765 0 6-8-3 Temperature upstream DOC, temperature above upper shutoff threshold.
1040 4765 0 6-8-3 Temperature upstream DOC, temperature above upper warning threshold.
1044 4768 3 6-8-3
Electrical error exhaust gas temperature upstream (DOC); signal range
check high.
1045 4768 4 6-8-3
Electrical error exhaust gas temperature upstream (DOC); signal range
check low.
1047 3248 4 6-8-5 Sensor error particle filter downstream temperature; signal range check low.
1067 1180 3 5-5-6
Sensor error exhaust gas temperature upstream turbine; signal range check
high.
1069 4360 0 6-6-8
Exhaust temperature upstream SCR-Cat, temperature above upper physical
threshold.
1070 4360 1 6-6-8 Sensed exhaust temperature before SCR-Cat is < physical low limit.
1071 4361 2 6-6-8 Signal error for CAN message No detail informationen!
1166 523948 1 7-7-2 Zerofuel calibration injector 3 (in firing order); minimum value exceeded.
1167 523949 1 7-7-2 Zerofuel calibration injector 4 (in firing order); minimum value exceeded.
1168 523950 1 7-7-2 Zerofuel calibration injector 5 (in firing order); minimum value exceeded.
1170 523612 12 5-5-5 Internal software error ECU.
1180 168 0 3-1-8 Physical range check high for battery voltage.
1181 168 1 3-1-8 Physical range check low for battery voltage.
1183 172 1 2-2-6 Air inlet filter sensor out of physical range check.
1187 523980 14 7-8-4 Bad quality of reduction agent detected.
1193 1180 0 5-5-6 Physical range check high for exhaust gas temperature upstream turbine.
1194 1180 1 5-5-6 Physical range check low for exhaust gas temperature upstream turbine.
1513AA-14
To order go to Discount-Equipment.com

Table of Contents

Other manuals for Skyjack SJ82 T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skyjack SJ82 T and is the answer not in the manual?

Skyjack SJ82 T Specifications

General IconGeneral
BrandSkyjack
ModelSJ82 T
CategoryBoom Lifts
LanguageEnglish

Related product manuals