173
SJ85 AJ 229044ADA
Deutz Diesel Engines Section 5 – Procedures
5.6-6 Deutz TD2.9L Fault Codes
Code SPN FMI Blink Code Error Identification
122 523698 11 5-9-1 Shut off request from supervisory monitoring function.
124 523969 11 7-7-4 Fault entry for override control mode.
125 523717 12 5-9-5 Timeout error of CAN-transmit-frame AmbCon; Weather environments.
126 523603 9 3-3-8 Timeout Error of CAN-receive-frame AMB; Ambient temperature sensor.
128 3224 9 5-9-7 Timeout error of CAN-receive-frame AT1IG1; NOX sensor upstream.
129 3224 2 5-9-6 DLC error of CAN-receive-frame AT1IG1Vol NOX sensor.
130 3224 9 5-9-7 Timeout error of CAN-receive-frame AT1IG1Vol; NOX sensor.
133 523938 9 7-6-6 Timeout error (BAM to packet) for CAN-receive-frame AT1IGCVol1.
134 523939 9 7-6-6
Broadcast announce message of the calibration message of the upstream
catalytic NOx sensor has failed.
135 523940 9 7-6-6 Timeout error (PCK2PCK) for CAN-Receive-Frame AT1IGCVol1.
136 3234 2 1-1-4 DLC error of CAN-Receive-Frame AT1O1.
137 3234 9 1-1-7
Timeout error of CAN-Receive-Frame AT1OG1. NOX sensor (SCR-system
downstream cat; DPF-system downstream cat).
138 3234 2 1-1-4 DLC error of CAN-Receive-Frame AT1O1Vol.
139 3234 9 1-1-7 Timeout error of CAN-Receive-Frame AT1OG1Vol.
140 523941 9 7-6-7 Timeout error (BAM to packet) for CAN-Receive-Frame AT1OGCVol2.
141 523942 9 7-6-7 Calibration message 1 of the after catalyst Nox sensor has failed.
142 523943 9 7-6-7 Timeout error (PCK2PCK) for CAN-Receive-Frame AT1OGCVol2.
153 523992 9 7-9-3 Not used.
155 0 0 - Not used.
164 523211 9 3-3-1 Timeout error of CAN-Receive-Frame EBC1.
167 523704 12 6-1-5 Timeout error of CAN-Transmit-Frame EEC3.
168 523935 12 7-6-3 Timeout error of CAN-Transmit-Frame EEC3VOL1. Engine send messages.
169 523936 12 7-6-4 Timeout error of CAN-Transmit-Frame EEC3VOL2. Engine send messages.
171 523212 9 3-3-3 Timeout error of CAN-Receive-Frame ComEngPrt. Engine Protection.
172 523741 14 6-1-8 Engine shut off request through CAN.
174 523213 12 3-3-4 Timeout error of CAN-Transmit-Frame ERC1.
178 523706 12 6-2-3 Timeout error of CAN-Transmit-Frame FlEco.
179 523240 9 5-2-7 Timeout CAN-message FunModCtl. Function Mode Control.
193 523937 9 7-6-5 Timeout DFC for NOxSensGlbReqTx.
196 3227 2 6-3-8 DFC SAE J1939 error.
198 523216 9 3-3-7
Timeout error of CAN-Receive-Frame PrHtEnCmd. Pre-heat command, en-
gine command.
202 523793 9 6-7-8 Timeout error of CAN-Receive-Frame UAA10. AGS sensor service message.
203 523794 9 6-7-8 Timeout error of CAN-Receive-Frame UAA11. AGS sensor data.
212 523803 9 6-7-8 Timeout error of CAN-Receive-Message RxEngPres. Status Burner Air Pump.
1513AA-3
To order go to Discount-Equipment.com

Table of Contents

Other manuals for Skyjack SJ85 AJ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skyjack SJ85 AJ and is the answer not in the manual?

Skyjack SJ85 AJ Specifications

General IconGeneral
BrandSkyjack
ModelSJ85 AJ
CategoryBoom Lifts
LanguageEnglish

Related product manuals