174
SJ85 AJ229044ADA
Section 5 – Procedures Deutz Diesel Engines
5.6-6 Deutz TD2.9L Fault Codes
Code SPN FMI Blink Code Error Identification
273 3219 2 6-4-9 DFC SAE J1939 error.
281 523766 9 1-1-8 Timeout error of CAN-Receive-Frame Active TSC1AE.
282 523767 9 1-1-8 Timeout error of CAN-Receive-Frame Passive TSC1AE.
283 523768 9 1-1-9 Timeout error of CAN-Receive-Frame Active TSC1AR.
284 523769 9 1-1-9 Timeout error of CAN-Receive-Frame Passive TSC1AR.
291 523776 9 1-1-9 Timeout error of CAN-Receive-Frame TSC1TE - active.
292 523777 9 1-1-9 Passive timeout error of CAN-Receive-Frame TSC1TE. Setpoint.
293 523778 9 1-1-8 Timeout error of CAN-Receive-Frame TSC1TR.
294 523779 9 1-1-8 Passive timeout error of CAN-Receive-Frame TSC1TR.
299 523788 12 6-5-5 Timeout error of CAN-Transmit-Frame TrbCH. Status Wastegate.
300 523605 9 1-1-8 Timeout error of CAN-Receive-Frame TSC1AE. Traction Control.
301 523606 9 1-1-9 Timeout error of CAN-Receive-Frame TSC1AR. Retarder.
305 898 9 1-1-8 Timeout error of CAN-Receive-Frame TSC1TE. Setpoint.
306 520 9 1-1-9 Timeout Error of CAN-Receive-Frame TSC1TR; control signal
313 523858 12 6-7-9 Timeout error of CAN-Transmit-Frame UAA11.
322 523867 12 6-7-9
Timeout error of CAN-Transmit-Frame UAA1 on CAN 2. Control burner air
pump.
360 523982 0 7-3-7 Powerstage diagnosis disabled. High battery voltage.
361 523982 1 7-3-7 Powerstage diagnosis disabled. Low battery voltage.
362 523090 2 3-2-9 Engine brake Pre-Selection switch. Plausibility error.
376 630 12 2-8-1 Access error EEPROM memory (delete).
377 630 12 2-8-1 Access error EEPROM memory (read).
378 630 12 2-8-1 Access error EEPROM memory (write).
381 411 4 6-9-3 Physical range check low for EGR differential pressure.
384 2791 12 4-1-5 Actuator EGR valve. Powerstage over temperature.
387 523612 12 5-5-5 Internal software error ECU. Injection cut off.
388 190 0 2-1-4
Engine speed above warning threshold.
Overspeed detection in component engine protection.
389 190 0 2-1-4 Engine speed above warning threshold (FOC-Level 1).
390 190 11 2-1-4 Engine speed above warning threshold (FOC-Level 2).
391 190 14 2-1-4 Engine speed above warning threshold (Overrun Mode).
411 108 11 2-9-2 Ambient air pressure received from a CAN-bus is reported as defective.
412 108 3 2-9-2 Sensor error ambient air pressure. Signal range check high.
413 108 4 2-9-2 Sensor error ambient air pressure. Signal range check low.
415 171 0 3-1-2
Environment temperature sensor, temperature above upper physical thresh-
old.
416 171 1 3-1-2 Environment temperature physical range check low.
1513AA-4
To order go to Discount-Equipment.com

Table of Contents

Other manuals for Skyjack SJ85 AJ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skyjack SJ85 AJ and is the answer not in the manual?

Skyjack SJ85 AJ Specifications

General IconGeneral
BrandSkyjack
ModelSJ85 AJ
CategoryBoom Lifts
LanguageEnglish

Related product manuals