EasyManuals Logo

Skyjack SJ85 AJ Service Manual

Skyjack SJ85 AJ
207 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #184 background imageLoading...
Page #184 background image
188
SJ85 AJ229044ADA
Section 5 – Procedures Deutz Diesel Engines
5.6-6 Deutz TD2.9L Fault Codes
Code SPN FMI Blink Code Error Identification
1439 524034 4 8-1-6 Disc separator; short circuit to ground.
1440 524030 7 8-1-5 EGR actuator; internal error.
1441 524031 13 8-1-5 EGR actuator, calibration error.
1442 524032 2 8-1-5 EGR actuator; status message "EGRCust" is missing.
1443 524033 7 8-1-5 EGR actuator; due to overload in Save Mode.
1455 3711 12 7-1-1 Temperature during stand-still main phase too low or too high.
1458 523960 0 7-7-1
High exhaust gas temperature EGR cooler downstream; warning threshold
exceeded.
1464 0 0 -
1466 0 0 -
1467 0 0 -
1469 0 0 -
1470 0 0 -
1471 0 0 -
1472 0 0 -
1481 524025 5 8-4-5 DPF system; operating voltage error.
1482 524044 9 1-8-8 CAN message ComMS_Sys7 not received from slave.
1484 524068 2 8-9-5 Master ECU and Slave ECU have been identified as the same types.
1485 524052 11 8-3-6 Master ECU and Slave ECU data sets or software are not identical.
1486 523718 5 6-7-6 SCR mainrelay; open load (only CV56B).
1488 523718 3 6-7-6 SCR mainrelay; short circuit to battery (only CV56B).
1489 523718 4 6-7-6 SCR mainrelay; short circuit to ground (only CV56B).
1661 524116 9 1-9-4 Timeout error of CAN-Transmit-Frame SCR2.
1662 524117 9 9-4-1 Timeout error of CAN-Transmit-Frame SCR3.
1663 524097 9 9-2-1 Timeout error of CAN-Transmit-Frame DPFBrnAirPmpCtl.
1664 524098 9 9-2-2 Timeout error of CAN-Transmit-Frame ComDPFBrnPT.
1665 524099 9 9-2-3 Timeout error of CAN-Transmit-Frame ComDPFC1.
1666 524100 9 9-2-4 Timeout error of CAN-Transmit-Frame ComDPFHisDat.
1667 524101 9 9-2-5 Timeout error of CAN-Transmit-Frame ComDPFTstMon.
1668 524105 9 9-2-9 Timeout error of CAN-Transmit-Frame ComEGRMsFlw (EGR Steller).
1669 524108 9 9-3-2 Timeout error of CAN-Transmit-Frame ComEGRTVActr (EGR actuator).
1670 524110 9 9-3-4 Timeout error of CAN-Transmit-Frame ComETVActrTO.
1671 524112 9 9-3-6 Timeout ComIntake Throttle Valve Actr.
1672 524118 9 9-4-2 Timeout error of CAN-Receive-Frame ComRxCM1.
1675 524103 9 9-2-7 Timeout error of CAN-Receive-Frame ComRxDPFBrnAirPmp.
1676 524104 9 9-2-8 Timeout error of CAN-Receive-Frame ComRxDPFCtl.
1513AA-18
To order go to Discount-Equipment.com

Table of Contents

Other manuals for Skyjack SJ85 AJ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skyjack SJ85 AJ and is the answer not in the manual?

Skyjack SJ85 AJ Specifications

General IconGeneral
BrandSkyjack
ModelSJ85 AJ
CategoryBoom Lifts
LanguageEnglish

Related product manuals