13 Directory of the Parameters in Installer Mode and Expert Mode SMA Solar Technology AG
88 SI60H-80H-BE-en-20 Operating Manual
113# Slave1
112.12 TrfTmp Temperature of the transformer in °C (expert
mode)
The temperature of the transformer is displayed in
the master of a cluster.
‒‒
112.13 HsTmp Temperature of the heat sink in the Sunny Island in
°C (expert mode)
The temperature of the heat sink is displayed in
the master of a cluster.
‒‒
No. Name Description Value Explanation
113.01 InvOpSttSlv1 Operating state of slave 1 Init (1) Initialization
Startup (2) Switch from standby to operation
Standby (3) Standby
Run (4) Operation
I-Loop (5) Current-controlled generator
operation
Error (6) Error status
113.02 InvPwrAtSlv1 Active power of slave 1 in kW ‒ ‒
113.03 InvVtgSlv1 Voltage of slave 1 in V ‒ ‒
113.04 InvCurSlv1 Current of slave 1 in A ‒ ‒
113.05 InvPwrRtSlv1 Reactive power of slave 1 in kVAr
(expert mode)
‒‒
113.06 Rly1SttSlv1 State of multifunction relay 1 in
slave 1
Off Multifunction relay is deactivated.
On Multifunction relay is activated.
113.07 Rly2SttSlv1 State of multifunction relay 2 in
slave 1
Off Multifunction relay is deactivated.
On Multifunction relay is activated.
113.09 TrfTmpSlv1 Temperature of the transformer in
slave 1 in °C (expert mode)
‒‒
113.10 HsTmpSlv1 Temperature of the heat sink in
slave 1 in °C (expert mode)
‒‒
No. Name Description Value (plain text
no.)
Explanation