APPENDIX B
REMOTELY MANAGING YOUR SYSTEM THROUGH AN RS-232 SERIAL INTERFACE
64 smarttech.com/kb/170549
Command Response Powered off
set sysoutputsw
[target]
sysoutputsw=[current] no
get sysoutputsw sysoutputsw=[current] no
Field definitions
Field Possible values Description
target volume l + val
l val
l = -20 to 20
Use + or to change the volume incrementally.
Enter a number within the range to set the
volume to a specific level. When you modify
the volume using the RS-232, the OSD's
volume slider matches the slider that appears
when you use another control. Note that -20
should map to 0 and 20 should map to 40.
current volume
Range: -20 to 20
The device’s current volume. Note that -20
should map to 0 and 20 should map to 40.
target mute l = on
l = off
Specifies whether mute is enabled or disabled.
current mute l = on
l = off
Current state of the mute function
current volumecontrol l = on
l = off
Current state of the volume control
target volumecontrol l = on
l = off
Specifies whether volume control is enabled or
disabled.
target cc l = cc1
l = cc2
l = off
Closed captioning states
current cc l = cc1
l = cc2
l = off
Closed captioning states
target sysoutputsw l = line+spkr
l = line
l = spkr
l = none
Specifies the system output switch