APPENDIX B
REMOTELY MANAGING YOUR SYSTEM THROUGH AN RS-232 SERIAL INTERFACE
75 smarttech.com/kb/170549
Field
Possible Values
Description
target colorwheelidx = ??? The ranges must match the OSD ranges.
current colorwheelidx ??? The ranges must match the OSD ranges.
current failurelog
l
normal
l
overtemp
l
fanlock
l
fanDMD
l
fanblower
l
fansystem
l
lamperror
l
colorwheelbreak
l
lampignite
l
lampoverheat
l
lampdriver
l
lampoverhours
Projector's error state. The modes are projector
dependent.
Current error# Provide the details of
the specific error. “#”
is the number
recorded in the log. It
ranges from 1 to 5. 1
indicates the most
recent error and 5
indicates the oldest
error.
The details include the failure reason, system
hours, lamp hours, sensor temperature and
lamp voltage.
Example: error1=fansystem, syshrs:1000,
lamphrs=1000, temp=60,volt=120.
error2=lampoverheat, syshrs:3000,
lamphrs=2900, temp=150,volt=120.
target factoryreset
l
= true
l
= false
If set to true,” perform a factory reset.
Otherwise, do nothing.
current factoryreset
l
= true
l
= false
Set to “true only if a factory reset is about to
occur.
target highspeedfan
l
= high
l
= normal
Must match the OSD settings.
current highspeedfan
l
high
l
normal
Must match the OSD settings.
current statereporting
l
on
l
off
Current state reporting value