COSMOS DRIVER SERIES 3000 - USE AND MAINTENANCE MANUAL
7.2.7.2 Models for asynchronous motor
Menu Entry Lev. Description
1.4
>MOTOR
- In this section it is possible to set the parameters of
the motor type in use.
1.4.1
I RMS [mA]
3 Motor rated current.
1.4.2
I PEAK MAX [mA]
3 Motor maximum peak current. This is the limit for
the maximum instant current that can be supplied to
the motor.
This parameter is a protection for the application.
1.4.3
NTC TYPE
3 It selects the type of NTC sensor for detecting the
motor temperature.
Options:
None (NTC absent ), B57227K.
1.4.4
TEMP MAX
[°C]
3 Maximum temperature allowed for the motor.
Min 0°C, Max 155 °C.
Ver. 1.07 Pag. 71