Chapter 6
Maintenance
The RO1 robot and controller are designed for long life with minimal maintenance. If the robot is installed
according to the intended use instructions the robot and controller will provide years of service.
6.1 User-Serviceable Parts
Part Description Part # Replacement Interval
Control Box Fan
Filter
120mm Sq Nylon Mesh 8 Micron
Filter
SB-0596-
A
6 months, application
dependent
6.2 Replacement Procedures
6.2.1 Controller Fan
1. Stop the robot.
2. Apply the robot brakes through the Move Robot view in the user interface.
3. Unplug the controller.
4. Wait 30 seconds for power to dissipate.
5. Tape up the area as shown below to avoid damaging surface:
88