– Close the cylinder valve (1).
– Securely grip the connection nipple using
the handhold (3) and carefully (2) loosen
the union nut (left-hand thread).
– Swivel the handle of the tensioning device
(4) upwards and remove the hook (6) from
the support mounting.
– Remove the upper part of the cylinder hold-
er (5).
– Exchange the empty gas cylinder for a full
one.
– When installing the gas cylinder, make sure
that the connection screw joint of the cylin-
der shut-off valve points vertically down-
wards.
– Secure the gas cylinder properly in the cyl-
inder holder.
– Open the cylinder valve (1) by slowly turn-
ing the star-grip handle anti-clockwise.
– Check whether the hose or connection
screw joints have iced over.
DANGER
There is a risk of explosion if LPG es-
capes!
Do not start the engine if there is a leak-
age, gas smell etc.
– Close the cylinder valve again.
– Notify your supervisor or the author-
ised service centre.
1
2
3
7311_136-001
4
7311_136-002
5
6
Operation
4
Refuelling
27357348011850 EN - 08/2020 - 12

Table of Contents