Observe the national regulations in the rele-
vant country! In Germany, perform checks in
accordance with § 37 of the employers' liability
insurance association regulations BGV D34
entitled "Accident prevention regulation for the
use of LPG".
The type and scope of tests may differ accord-
ing to the country. Any differing legal provi-
sions in the respective country of operation
must be observed when using trucks with an
LPG system.
NOTE
Please observe the definition of the following
responsible persons: "operating company"
and "competent person".
Insulation testing
The truck insulation must have sufficient insu-
lation resistance. For this reason, insulation
testing in accordance with DIN EN 1175 and
DIN 43539, VDE 0117 and VDE 0510 must be
conducted at least once every year.
NOTE
Contact your service centre to arrange for an
insulation test.
Measuring the insulation resistance of
the electrical system
NOTE
Nominal battery voltage < test voltage <
500 V.
– Ensure that all voltage sources have been
disconnected from the circuit to be tested.
– Measure the insulation resistance with a
suitable measuring device.
The insulation resistance can be considered
sufficient if it measures at least 1000 Ω/V for
nominal battery voltage against ground.
– Contact the authorised service centre.
Safety
2
Safety tests
40 57348011850 EN - 08/2020 - 12