– Close the cylinder valve (1) of the gas cylin-
der to be changed.
– Securely grip the connection nipple using
the handhold (3) and carefully loosen the
union nut (2) (left-hand thread).
– Swivel the handle of the tensioning device
(4) upwards and remove the hook (5) from
the holder.
– Remove the upper part of the cylinder hold-
er (6).
– Remove the empty gas cylinder and screw
on the cylinder cap (7).
– Install the full gas cylinder.
– When installing the gas cylinder, make sure
that the connection screw joint of the cylin-
der shut-off valve points vertically down-
wards.
– Insert the upper part of the cylinder holder.
– Fit the hook to the holder and swivel the
handle of the tensioning device downwards.
– Securely grip the connection nipple using
the handhold and screw on the union nut.
– Open the cylinder valve by slowly turning
the star-grip handle anti-clockwise.
– Check to see whether the hose and con-
nection screw joints have iced over.
1
6
2
3
7
5
4
Operation
4
Refuelling
27557348011850 EN - 08/2020 - 12