Objet350 User Guide 6 Operating and Maintaining the Objet350 3D๎Printer
DOC-17001 Rev.๎G 6-83
Test Name Description Possible Reason for Failure
Head/Block๎Heaters Tests๎the๎heaters๎in๎the๎print๎heads๎
and๎in๎the๎print-block๎body.
Faulty๎heaters๎or๎thermistors.
UV๎Lamps Tests๎each๎UV๎lamp๎at๎the๎High๎
Quality๎power๎level.
Faulty๎UV๎lamp.
Faulty๎UV๎power๎supply.
Disconnected๎UV๎cable.
Axes๎Limit Tests๎the๎hardware๎and๎software๎
limits๎of๎all๎axes.
Faulty๎hardware๎sensors.๎
Wrong๎Max Position๎parameter.
Parameter๎Sanity๎
Check
Compares๎the๎values๎of๎all๎printer๎
parameters๎(in๎cfg๎files)๎to๎the๎
required๎values.
One๎or๎more๎of๎the๎printer๎parameters๎
is๎not๎within๎the๎required๎range.๎
Details๎appear๎in๎the๎BIT๎report.
Vacuum Tests๎the๎vacuum๎level๎in๎the๎print๎
block.
โข๎ Faulty๎vacuum๎sensor.๎
โข๎ Vacuum๎leakage.๎
โข๎ Wrong๎parameters.