5.10 Cleaner
Table5-8showsthecompletelistofsettingsyoucanmakeunderthesubmenuCleaner.
Table 5-8 Cleaner,under‘Settings>Cleaner
Submenu Submenu Setting Value Passcode Comment
- Flushat:
(PumpStart,
Pump Stop)
System
- Flushing Time Seconds
- No.StarttoFlush Integer
5.11 Analog logging
Table5-9showsthecompletelistofsettingsyoucanmakeunderthesubmenuAnalog Logging.
Table 5-9 Analoglogging,under‘Settings>AnalogLogging’
Submenu Submenu Setting Value Passcode Comment
Log Channel 1 to Log Channel 16
Log Signal
(Closed,
PitLevel,
PitInow,
PitOutow,
OverowLevel,
OverowFlow,
Back-Pressure,
MotorCurrent,
PumpCapacity,
PowerFactor,
Temp.Stator,
Temp.UpperBearing,
Temp.LowerBearing,
Vibrations,
MainVoltage,
MainFrequency,
FreeChoice,
SupplyVoltage,
PulseChannel,
Temperature Stator
WiringL2,
Temperature Stator
WiringL3,
PidControlleroutput,
DataRegister,
DataRegister
(2-compl.),
ActualVFDfrequency
P1-P4,
TotalHead,
Actual Head)
System
A total of 16 analog channels
whoseoutputsyoucanchoose
from the list.
Pulse Channelareusedforrain,
owandenergyvalues.
Temperaturesignalsareonly
meaningfulifyouusePT100
sensors.
Forsomesignalsyouhaveto
choose pump number or pulse
channel.
Log Function
(Closed,
ActualValue,
AverageValue,
MinValue,
MaxValue)
Log Interval Minutes