S One User’s Manual
OPOS 3-16
The cutter will make a circular movement while it measures the reflection of the mark colour.
Then a value is shown that is typical for this combination of media colour - mark colour. Save
this value for future use.
NOTE: An error message may appear if the sensor is not able to differentiate
between black and white. Make sure that the test has been performed correctly.
Set value:
If a combination of media colour – mark colour has already been calibrated and set, this value
can be entered directly. Follow the procedure on the previous page up to and including step
4, then continue with the steps below.
6. Use the arrows to change the
value or enter a value.
Default value:
Follow the procedure on the previous page up to and including step 4, then perform the
following action:
Measure
Set
Reset default
Calibrate media (OPOS)
OPOS sensor level
1 2 3 0
4 5 6
7 8 9 C
80
80
OPOS sensor level
1 2 3 0
4 5 6
7 8 9 C
80
80
Measure
Set
Reset default
Calibrate media (OPOS)