Service Manual SummaSign series Cutters
LCD information Parity setting Remarks
BIT 8 = 0
8 data bits, no parity bit 8 = low (0)
BIT 8 = 1
8 data bits, no parity bit 8 = high (1)
EVEN
7 data bits, 1 parity bit parity bit = even
ODD
7 data bits, 1 parity bit parity bit = odd
On the LCD, the active parity setting is marked with an *.
NOTE
The parity setting of your cutter MUST match the host computer's parity
setting.
RTS/DTR
The RTS/DTR submenu controls the Request To Send (RTS) and Data Terminal
Ready (DTR) signals of the cutter's RS-232-C serial communications interface for
hardware handshaking.
The RTS/DTR default value is TOGGLE.
RTS/DTR can be set to TOGGLE (hardware handshaking) or HIGH (software
handshaking).
On the LCD, the active handshaking setting is marked with an *.
Keyboardcontrols 1-15