88
figure 7-18 Reactive Power Regulation
table 7-10 Reactive Power Regulation
Parameter
Definition/Setting
Description
Range
Reactive power gener-
ation at night
Switch for enabling/disabling
reactive power generation at
night function.
Enable/Disable
Reactive power ratio
at night
Reactive power ratio set for
the reactive power generation
at night function.
-100%~0%/
0%~100%
Reactive power setting
persistence
Switch for enabling/disabling
the power-off function during
reactive power.
Enable/Disable
Reactive power regu-
lation mode
Off/PF/Qt/Q(P)/Q(U)
The inverter provides the reactive power regulation function. Enable this function under "Re-
active Power Regulation Mode" and select the appropriate mode.