90
PPaarraammeetteerr
SSGG1155RRTT SSGG1177RRTT SSGG2200RRTT
OOuuttppuutt ((AACC))
Nominal AC output power
15000 W 17000 W 20000 W
Max. AC output apparent
power
15000 VA for
"AU", "BE", "DE",
16500 VA for
others
17000 VA for
"AU", "BE", "DE",
18700 VA for
others
20000 VA for
"AU", "BE", "DE",
22000 VA for
others
Max. AC output current
25.0 A 28.3 A 31.9 A
Max. inrush current (peak/
duration)
20 A / 5 ms
Max. output fault current
(peak/duration)
100 A / 5 us
Nominal AC voltage
3 / N / PE, 220 V / 230 V / 240 V
AC voltage range 180 V AC–276 V AC (this may vary with grid standards)
Nominal grid frequency 50 Hz / 60 Hz
Grid frequency range 45 Hz–55 Hz / 55 Hz–65 Hz (this may vary with grid
standards)
Total Harmonic Distortion
(THD)
< 3 % (of nominal power)
DC current injection < 0.5 % (of nominal current)
Power factor > 0.99 at default value at nominal power (adj. 0.8
overexcited/leading–0.8 underexcited/lagging)
PPrrootteeccttiioonn
Grid monitoring
Yes
DC reverse connection
protection
Yes
AC short circuit protection
Yes
Leakage current
protection
Yes
Anti-islanding protection Yes
DC switch
Yes
PID recovery function Yes
Arc fault circuit interrupter
(AFCI)
Optional
Surge protection DC Type II, AC Type II
Overvoltage category
III [Main], II [PV]
SSyysstteemm DDaattaa
Max. efficiency
98.50 %
European efficiency
98.10 %