71
FFiigguurree 77--1177 Reactive Power Regulation
Table 7-9 Description of Reactive Power Regulation Parameters
PPaarraammeetteerr
DDeessccrriippttiioonn RRaannggee
Reactive Power Setting
Persistence
Switch for activating/deactivating the
function of reactive power setting
persistence
On/Off
Reactive Power
Regulation Mode
See "7.4.2 For Germany"
Off/PF/Qt/Q
(P)/Q(U)
Reactive Response
Switch for activating/deactivating the
function of reactive response
On/Off
Reactive Response
Time
Time for reactive response
0.2 s
Please refer to "7.4.2 For Germany" for the parameter explanation of each reactive
power regulation mode.
7.9.4 Communication Parameters
Tap SSeettttiinnggss→→CCoommmmuunniiccaattiioonn PPaarraammeetteerrss to enter the corresponding screen, as
shown in the following figure. The device address ranges from 1 to 246.
FFiigguurree 77--1188 Communication Parameters
7.9.5 Firmware Update
PPrreeppaarraattiioonn
Contact the supplier or SUNGROW to get the upgrade package (.sgu file) and store the
package in the specified path.
• Path (Android system): root directory / iscFiles
• Storage method (iOS system): Connect the mobile phone to the computer through a
data cable, find the folder iSolarCloud application via iTunes, iMazing or iTools, and
User Manual 7 iSolarCloud App