71
FFiigguurree 77--1177 Reactive Power Regulation
Table 7-9 Description of Reactive Power Regulation Parameters
PPaarraammeetteerr
DDeessccrriippttiioonn RRaannggee
Reactive Power Setting
Persistence
Switch for activating/deactivating the
function of reactive power setting
persistence
On/Off
Reactive Power
Regulation Mode
See "7.4.2 For Germany"
Off/PF/Qt/Q
(P)/Q(U)
Reactive Response
Switch for activating/deactivating the
function of reactive response
On/Off
Reactive Response
Time
Time for reactive response
0.2 s
Please refer to "7.4.2 For Germany" for the parameter explanation of each reactive
power regulation mode.
7.9.4 Communication Parameters
Tap SSeettttiinnggssCCoommmmuunniiccaattiioonn PPaarraammeetteerrss to enter the corresponding screen, as
shown in the following figure. The device address ranges from 1 to 246.
FFiigguurree 77--1188 Communication Parameters
7.9.5 Firmware Update
PPrreeppaarraattiioonn
Contact the supplier or SUNGROW to get the upgrade package (.sgu file) and store the
package in the specified path.
Path (Android system): root directory / iscFiles
Storage method (iOS system): Connect the mobile phone to the computer through a
data cable, find the folder iSolarCloud application via iTunes, iMazing or iTools, and
User Manual 7 iSolarCloud App