30
Observe the plug assignment. Do not connect any phase line to the "PE"
terminal or PE wire to "N" terminal. Otherwise, unrecoverable damage to the
inverter may follow.
Step 8 Ensure that the wires are securely in place by slightly pulling them. Tighten the swivel
nut to the housing.
-- -- EEnndd
5.5.5 Installing the AC Connector (≥ 15 kW)
High voltage may be present in inverter!
Ensure all cables are voltage-free before electrical connection.
Do not connect the AC circuit breaker until all inverter electrical connections are
completed.
Step 1 Disconnect the AC circuit breaker and secure it against reconnection.
Step 2 Remove the waterproof lid from the AACC terminal.