40
(2) Edge Sensor Setup
① While the button is being pressed, turn on the power.
② While the switch is being pressed, press button to enter the Parameter C
Group.
③ Use the and buttons to set the Parameter C Group at 52. Use the and
buttons to change the dalue of 2 to 12.
④ After going through the above processes ~ , press to save the new value.
Press the button to exit the parameter setup mode.
⑤ After undergoing the above processes ~ , press the button. When the LED is
on, the sensor is working.
Pressing the edge sensor button makes sewing motion stop when the sewing material edge is detected. For proper
implementation of the function, have a thorough understanding of “Section (4) Use of Detailed Edge Sensor
Functions” in the manual before use.
Caution
⇒
(3) Edge Sensor Sensitivity Setup
① Without a sewing material located under the sensor, set the operating mode on the
back of the sensor at L.ON.
② Press the button and the lamp blinks. Place a sewing material under the sensor
and check if the STB lamp (amber) in front of the sensor blinks.
③ In the event that the STB lamp(amber) in front of the sensor is not turned on, change
the operating mode on the back of the sensor to D.ON and repeat the process
again.
(The reason of the lamp turned off is the edge sensor reacts depending on sewing
material types.)
④ After undergoing the above processes ~ , adjust the SENS volume on the sensor
front to make sure that the OPL lamp(Red) remains turned off when the sewing
material is below the sensor and that the OPL lamp(Red) blinks when the sewing
material is not below the sensor.
At this time, the blinking of the STB lamp(amber) does not matter.