IntelliShot & FlexoShot: Operations Manual Page 29
PRODUCT COMPARTMENT
Cleaning and drying the product compartment each time a new dairy bag, bag-in-box or refillable tank
is loaded will remove condensation and improve the efficiency of the dispenser.
Occasionally, ice may form in the product compartment. This does not necessarily mean the
temperature of the product compartment is too cold. The dispenser is not a frost-free system;
therefore, some ice will be present under normal operation.
1. Turn off the dispenser and open the door.
2. Remove the product case(s), refillable tank(s), or Bag-in-Box and ramp(s) from the product
compartment.
3. With the dispenser door open, wait approximately 15 minutes for ice to soften.
4. Wipe product compartment with a clean dry cloth to remove the ice.
5. Use a soft cloth dampened with warm, clean, soapy water to wipe inside the product compartment,
including inside the dispenser door.
6. Wipe using a soft cloth dampened with warm, clean water.
7. Dry thoroughly with a soft cloth.
8. Turn on the dispenser.
VALVE ASSEMBLY AND FRONT PANEL
The valve assembly holds the dispense tube in place and guides the plunger. Valve assemblies on
portion-control dispensers have a reed switch which is attached to the dispenser with a wire. The reed
switch sends a message to the dispenser each time the valve door is opened or closed. The reed
switch must be cleaned in place. Non-portion-control dispensers do not have a reed switch.
All dispensers (portion-control and non-portion-control) have one valve assembly with an attached
metal valve insert. The metal valve insert is attached with a thermistor wire to assist with temperature
control. All one-product dispensers and the left valve assembly on any multi-product dispenser has an
attached metal valve insert.
There is only one thermistor wire for each dispenser. For multi-product dispensers, the thermistor wire
is attached to the metal valve insert in the left valve assembly.
Before taking the valve assembly apart for cleaning, fill three containers with:
• warm, clean, soapy water,
• warm, clean rinse water; and
• sanitizing agent.
Do not dislodge any attached wires during cleaning.