TL1 Reference
097-72020-01 Issue 9: November 2003
2
5
3
SSSSSSSSSSSS SSSS S SSSSS SSSS SSS S SSS S SSSSS
44
Notes:
1. All commands on DCDUSERPORT TID which equal SID of the DCD are forwarded to
the DCD. Similarly, the responses from the DCD are sent to the provisioned DCDUSER-
PORT.
2. When setting alarm integration time (SEVERITY or SERAFF), the type of alarm
(HOLDOVER, GPS, LOS, AIS, or ERROR) has to be specified. For example, ED-
EQPT::TS3100:CTAG::: ALARM=HOLDOVER, TIME=72-00, SEVERITY1=EV,
SERAFF1=NSA, SEVERITY2=MJ, SERAFF2=SA; will generate a holdover event as
soon as the condition is detected with an NSA flag. Once this condition has existed for
72 hours, TS3100 will generate a major alarm with an SA flag. These parameters can then
be verified using the RTRV-EQPT command.
TS3100,
SPAN
A & B,
RO A & B
TIME=x x = HH-MM Hour (00-000) and minute (00-59) time to
escalate alarm
x = 0 No alarm escalation
SEV1=x
(see Note 2)
x = CR Severity of initial alarm prior to escalation
x = MJ
x = MN
x = EV
x = NA
SEV2=x
(see Note 2)
x = CR Severity of escalated alarm
x = MJ
x = MN
x = EV
x = NA
SAFF1=x
(see Note 2)
x = SA Service affecting state of initial alarm prior to
escalation
x = NSA
SAFF2=x
(see Note 2)
x = SA Service affecting state of escalated alarm
x = NSA

Table of Contents

Other manuals for Symmetricom TimeSource 3100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeSource 3100 and is the answer not in the manual?

Symmetricom TimeSource 3100 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeSource 3100
CategoryGPS
LanguageEnglish

Related product manuals