3
TimeSource 3100 75
Installation
097-72020-01 Issue 9: November 2003
2
5
3
SSSSSSSSSSS SSSS S SSSSS SSSS SSS S SSS S SSSSS S
Time of Day Output
If using Time of Day Output, connect the time of day (TOD) output at the female RJ-45
connector labeled TOD. See Figure 13 for the connector location, and Table C for the
connector pinouts.
Note: Pins not listed are reserved for future use.
If the device receiving the time code (for example, a Cisco router) accepts an RS-232 cable
instead of an RS-422 cable, follow Procedure D to install the RJ-45-to-DB-25 TOD
converter.
Note: Before performing Procedure D, ensure that the appropriate Cisco router or NTP type
4 compatible device is installed, and power applied, per manufacturer's instructions.
Table C. TOD Connector Pinouts
Pin Signal Abbreviation Direction
1 1 pps A TOD PPS + From TimeSource
3100
2 1 pps B TOD PPS – From TimeSource
3100
3 12 V power source TOD P12V —
4 Receive data B TOD RXD
–
To TimeSource 3100
5 Receive data A TOD RXD
+
To TimeSource 3100
6 Circuit ground TOD GND —
7 Transmit data A TOD TXD + From TimeSource
3100
8 Transmit data B TOD TXD – From TimeSource
3100