This command changes communication port parameters. The command format is:
ED-COM:[<tid>]:<aid>:<ctag>:::<spec_block>;
Notes:
1. Ethernet ports 5001, 5002, 5003, and 5004 are set up to act as serial communication ports,
so that a terminal program on a computer connected to these ports can communicate ef-
fectively.
2. Ethernet port 5551 is set up to allow an element manager to connect with it for TL1
commands and responses. TL1 autonomous messages are sent through port 5550, which
connects to an element manager to send one or a group of autonomous messages, then
disconnects. Port 5550 is not to be reconfigured.
Aid Value Item Addressed
COM-a a = 1 Serial communication port 1 (COM1)
a = 2 Serial communication port 2 (COM2)
a = 3 Serial communication port 3 (Craft)
a = 5001 Ethernet user interface port 5001 (Note 1)
a = 5002 Ethernet user interface port 5002 (Note 1)
a = 5003 Ethernet user interface port 5003 (Note 1)
a = 5004 Ethernet user interface port 5004 (Note 1)
a = 5551 Ethernet element manager interface port 5551
(Note 2)

Table of Contents

Other manuals for Symmetricom TimeSource 3100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeSource 3100 and is the answer not in the manual?

Symmetricom TimeSource 3100 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeSource 3100
CategoryGPS
LanguageEnglish

Related product manuals