OPERATION
TABLE 3-6
BCD Format Time Word Output
No Options
76543210
0000Word #1
Word #2
Word #3
Word #4
Word #5
Word #6
Word #7
HD
8421
UM
8421
421
UH
8421
TD
8421
US
8421
421
hS
8421
tS
8421
mS
8421
UH
8421
00
TH
21
0
TM
0
TS
0000
In order to output the format shown in Table 3-6, set the RS-232 select switches as follows:
(Specific configurations such as Mode and BAUD rate etc. aren’t shown).
SWITCH LOCATION
AND SECTION
SWITCH
POSITION
DESCRIPTION
S1 section 5 OFF (1) BCD selected on
S1 section 6 OFF (1) Preamble selected off
S1 section 7 OFF (1) Quality Indicator selected off
S1 section 8 OFF (1) Postamble selected off
S4 section 2 OFF (1) 8 Bit Word selected
S4 section 5 ON (0) Format Days-mS selected
S4 section 6 ON (0) Loss and Error bits disabled
Symmetricom, Inc. TM7000 TymMachine TCG/T (Rev D) 3-53