3-3
3.2 Environment requirement
a. Never put the machine in the places where sun shines directly on it.
b.
Temperature: normal range is between +5
and
40
.
c.
Humidity: between 30% and 95%. At the max. temperature 40
The relative
humidity should not be over 50
. And at the relative lower temperature, higher
humidity is acceptable. I.g. at temperature 20
,humidity 90
is fine.
d.
Please keep the machine away from gasoline, chemical substances, dust, acid, sulfides,
magnetic interference and explosive environment.
e. Please keep the machine away from the electrical interference source like welding
machine and EDM.
f. The installation ground must be flat.
g. The illumination of the work area: greater than 500lux.
h.
Good ventilation.
i. Please take care there is no hydraulic splash to prevent from anyone slipping tripping
and falling in danger.
3.3 Power supply requirement
a. Acceptable voltage fluctuation : normally ±
±±
±10%vlt.
b.
Acceptable frequency fluctuation : ±
±±
±1HZ (50/60HZ)
c. Acceptable momentary power-off duration: less than10m.sec
d.
Acceptable voltage impulse
The Peak value : 200% or less than the line voltage of the actual value(rms. value)
Duration: 1.5m.sec or less
e. Acceptable AC voltage of the waveform distortion.
f. Acceptable imbalance of the line voltage: 5% or less
g. Power capacity table
.For TPR-720A, TPR-820A, TPR-920A
Main Motor
1.5Kw
Elevating Motor 0.75Kw
Coolant Pump Motor 0.1Kw
The total power requirement should be 5.935KVA
.Only for TPR-1100
Main Motor
2.25Kw
Elevating Motor 0.75Kw
Coolant Pump Motor 0.1Kw
The total power requirement should be 7.853KVA

Table of Contents