OVP <NR2>
Function Sets the Over-Voltage Protection level. An attempt to adjust the OVP level below
voltage setting level will result in the execution error response (‘E04’) and the
OVP setting will stay unchanged.
Parameters OVP programming range is limited by:
1. 5% above voltage setting.
2. OVP programming range.
OVP programming range is given in Table 2-1.
Query
OVP?
Returns
<NR2> 4 digit format
OVM
Function Sets the Over-Voltage Protection to maximum. The OVP programming range is
given in Table 2-1.
UVL <NR2>
Function Sets the Under Voltage Limit. Value ‘n’ may be equal or less than 95% of PV
setting. Returns ‘E06’ if higher
Parameters Range is limited by the UVL programming range and voltage programmed value.
Refer to Table 2-2 for UVL programming range
Query
UVL?
Returns
<NR2> 4 digit format
UVP <Bool>
Function
Enable/Disable Under Voltage Protection
Parameters
0|1, OFF|ON
Query
UVP?
Returns
<Bool> 0|1
AST<Bool>
Function
Sets the auto-restart mode to ON or OFF
Parameters
0|1, OFF|ON
Query
AST?
Returns
<Bool> 0|1
SAV <NR1>
Function
Saves the power supply settings to a specific memory location
Parameters 1,2,3,4. SAV without a parameter stores the power supply settings in the
memory location 1