88
OVP <NR2>
Function Sets the Over-Voltage Protection level. An attempt to adjust the OVP level below
voltage setting level will result in the execution error response (‘E04’) and the
OVP setting will stay unchanged.
Parameters OVP programming range is limited by:
1. 5% above voltage setting.
2. OVP programming range.
OVP programming range is given in Table 2-1.
OVM
Function Sets the Over-Voltage Protection to maximum. The OVP programming range is
UVL <NR2>
Function Sets the Under Voltage Limit. Value ‘n’ may be equal or less than 95% of PV
setting. Returns ‘E06’ if higher
Parameters Range is limited by the UVL programming range and voltage programmed value.
Refer to Table 2-2 for UVL programming range
UVP <Bool>
Enable/Disable Under Voltage Protection
AST<Bool>
Sets the auto-restart mode to ON or OFF
SAV <NR1>
Saves the power supply settings to a specific memory location
Parameters 1,2,3,4. SAV without a parameter stores the power supply settings in the