AWVG7 Analog Wideband Video Generator module remote c ommands
:SENSe1:CORRe
ction:MDELay:VERTical <numeric_ value>
Sets the vertical timing offset of the output signals. The argument can be a
oating point
value that is translated into integer lines with a horizontal offset.
You can use UP, DOWN, or DEF instead of a numeric v alue.
:SENSe1:CO
RRection:MDELay:VERTical?
Returns the current vertical timing offset of the output signals.
:SENSe1:CORRection:MDELay: VERTical:STEP <numeric_value>
Sets the step increment used by the UP or DOWN commands. You c an use
MIN, MAX, or DEF instead of a numeric value.
:SENSe1:CORRection:MDELay: VERTical:STEP?
Returns the current step increment.