HD3G7 3 Gb/s SDI Video Generator module remote commands
Enables or disa
bles the Cb/B/Y color signal depending on the selected
sampling structure (see the:OUTPut1:SAMPling:SELect command).
:OUTPut1:ZON
E:VIDEO:PB:STATe?
Returns the state of the Cb/B/Y color signal.
:OUTPut1:ZONE:VIDEO:PR:ST ATe <0|1>
Enables or disables the Cr/R/Z color signal depending on the selected
sampling structure (see the:OUTPut1:SAMPling:SELect command).
:OUTPut1:ZONE:VIDEO:PR:ST ATe?
Returns the state of the Cr/R/Z color signal.
:OUTPut1:ZONE:DATa?
Returns
the Zoneplate data settings as a single block of data. Data is returned
as a sequence of integers, with parameters separated by commas. Data is
returned in the following format:
<Amp>,<Freq>,<kx>,<kx2>,<kxy>,<ky>,<ky2>,<k>,<kxt> , <kyt>,
<kt>,<kt2>,<Y>,<Pb>,<Pr>,<Waveform Shape>,<TReset>
SENSE commands
Use these commands to set the timing of the HD3G7 module relative to the
internal reference signal (frame reset signal).
Command tree
:SE
NSe1
:CORRection
:MDELay
:H
ORizontal
<NR1>
:HORizontal?
:VERTical
<NR1>
:Relative <ANALog|SERial>
C
ommand d escription
:SENSe1:CORRection:MDELay :HORizontal <NR1>
Sets the horizontal timing offset of the selected outputs. The timing resolution
is clock-cycles. The units are microseconds. See Table 2-6 for the delay
ranges.
Draft