DVG7 Digital Video Generator module remote commands
Turns the outpu
t mode for an audio/video timing measurement on or
off. Refer to Operating Basics in the T G8000 User Manual for detailed
information about the mode. You can also use 1 or 0 instead of ON or OFF.
:OUTPut1:VIDeo:AVTiming:S TATe?
Returns the
current output mode setting for an audio/video timing
measurement.
:OUTPut2:S
TANdard D2_NTSC|D1_NTSC|D1_PAL
Sets the video standard for the serial digital black signals output from the
BLACK conn
ectors. The choices are D2_NTSC (525-143 format), D1_NTSC
(525-270 format), or D1_PAL (625-270 format). This command is only
available if Option BK is installed.
:OUTPut<n>:STANdard?
Returns
the video standard for the selected output. The <n> in the command
represents the output connector type. "1" represents the SIGNAL connectors
and "2" represents the optional BLACK connectors.
:OUTPut2:SIGNal BLACk|GRAY|F F50P|WHITe
Sets t
he type of the serial digital black signals output from the BLACK
connectors. The options are BLACK (serial digital black signal) , GRAY
(40% at eld signal), FF50P (50% at eld signal), or WHITe (100% at
eld signal). This command is only available if Option BK is installed.
:OUTPut2:SIGNal?
Returns the current serial digital black signals output from the BLACK
connectors. This command is only available if Option BK is installed.
:OUTPut:CONFigure?
Re
turns the availability of serial digital black signal output option (Option
BK). "1" indicates that the option is available and "0" indicates that the option
is not available.
SENSE commands
Use these commands to set the timing offset of the SIGNAL outputs and the
BLACK outputs (Option BK only) relative to the internal reference signal (frame
reset signal).
Refer to Operating Basics in the TG8000 User Manual for detailed information
about the setting range.
Draft
74 TG8000 Multiformat Test Signal Generator Programmer Manual

Table of Contents

Other manuals for Tektronix TG8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TG8000 and is the answer not in the manual?

Tektronix TG8000 Specifications

General IconGeneral
BrandTektronix
ModelTG8000
CategoryPortable Generator
LanguageEnglish

Related product manuals