EasyManua.ls Logo

Tektronix TG8000 - Page 76

Tektronix TG8000
200 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BG7 Black Generator module remote commands
Sets the vertic
al timing offset of a specic BLACK output. The argument can
be a oating point value that is translated into integer lines with a horizontal
offset. You can use UP, DOWN, or DEF instead of a numeric value. The <n>
in the command represents the connector number. You can use a ny connector
number from 1 through 4.
:SENSe<n>:CORRection:MDEL ay:VERTical?
Returns the vertical timing offset of a specic B LACK output. The <n> in
the command represents the connector number. You can use any connector
number from 1 through 4.
:SENSe<n>:CORRection:MDEL ay:VERTical:STEP <numeric_value>
Sets the step increment used by the UP or DOWN commands. You can use
MIN, MAX, or DEF instead of the numeric values. The <n> in the command
represents the connector number. You can use any connector number from
1through4.
:SENSe<n>:CORRection:MDEL ay:VERTical:STEP?
Returns the step increment used by the UP or DOWN commands. The <n> in
the command represents the connector number. You can use any connector
number from 1 through 4.
Draft
64 TG8000 Multiformat Test Signal Generator Programmer Manual

Table of Contents

Other manuals for Tektronix TG8000

Related product manuals