After the update all AP setting. (country, RF,
conference,...) need to be reconfigured
Step 5:
First check if all units are connected via the
“Conference Management -> Unit Monitoring” tab.
In the DU update screen , browse to and select the
firmware_ wdu.bin ” file to update the DSP boot file
of the delegate unit.
First the file needs to be uploaded to the AP (“select
Upload to AP”). A green progress bar appears at the
bottom of the screen and after +/- 5 sec the screen
is refreshed.
Note:
During the update it is possible that the
stylesheet for the web pages are not loaded
correctly. After the complete update this
will be fixed.
If the connection is lost after a failed update
session then the hard coded web server link
has to be used to proceed with the update.
http://192.168.0.10/sublinks/update_main_
gold.shtml
Note:
After updating the WCAP SW , check
through the webserver “summary” section,
if the SW update has been successfull, as
some types of anti-virus SW and/or firewall
restrictions may block the updates of the
WCAP SW.
If needed disable the anti-virus SW for the
duration of the WCAP SW update.
Caution:
Before starting SW update of WDU, make
sure the batteries of ALL WDU’s are charged
up to at least 20% !
During WDU SW update procedure do not
move any WDU’s !
Updating SW of WDU’s with insufficient
batterycharge or while WDU’s are moved
around may result in slowdown of or even
failed update procedure !
Note:
Depending on the used
webbrowsertype and version , the
progressbar may not always be
visible.